VWRBS3-SIP Series DC-DC Converter
Rev. 07-2007
Description
Designed to convert a wide input voltage range into an isolated regulated voltage, the VWRBS3-SIP series is well suited for providing board-mount local supplies in a wide range of applications, including mixed analog/digital circuits, test & measurement equip., process/machine controls, datacom/telecom fields, etc...
Features
*Wide (2:1) input range *High efficiency to 84% *Regulated *Single voltage output *I/O Isolation 1500VDC *No heatsink required *Short circuit protection *Remote on/off *MTBF >1,000,000 hrs *Temperature range: -40C~+85C
Model Number VWRBS3-D12-S5-SIP VWRBS3-D12-S9-SIP VWRBS3-D12-S12-SIP VWRBS3-D12-S15-SIP VWRBS3-D24-S5-SIP VWRBS3-D24-S9-SIP VWRBS3-D24-S12-SIP VWRBS3-D24-S15-SIP
Nominal 12 Vdc 12 Vdc 12 Vdc 12 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc
Input Voltage Range 9.0~18.0 Vdc 9.0~18.0 Vdc 9.0~18.0 Vdc 9.0~18.0 Vdc 18.0~36.0 Vdc 18.0~36.0 Vdc 18.0~36.0 Vdc 18.0~36.0 Vdc
Max. 22 Vdc 22 Vdc 22 Vdc 22 Vdc 40 Vdc 40 Vdc 40 Vdc 40 Vdc
Output Voltage 5 Vdc 9 Vdc 12 Vdc 15 Vdc 5 Vdc 9 Vdc 12 Vdc 15 Vdc
Output Current Max. Min. 600 mA 0 mA 333 mA 0 mA 250 mA 0 mA 200 mA 0 mA 600 mA 0 mA 333 mA 0 mA 250 mA 0 mA 200 mA 0 mA
Efficiency 80% 82% 83% 84% 80% 82% 83% 84%
Package Style SIP SIP SIP SIP SIP SIP SIP SIP
Note: 1. All specifications measured at TA=25C, humidity <75%, nominal input voltage and rated output load unless otherwise specified.
Output Specifications
Item 3W Output power Output voltage accuracy Line Regulation Load Regulation Temperature drift Output ripple Output noise Switching frequency Test conditions Refer to recommended circuit Input Voltage from low to high 10% to 100% full load Refer to recommended circuit 20 Hz Bandwidth DC-20MHz Bandwidth 100% load, nominal input Min. 0.3 Typ. 1 0.2 0.5 20 80 200K Max. 3 3 0.5 0.75 0.03 50 150 400K Units W % % % %/C mVp-p mVp-p Hz
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
2/3
VWRBS3-SIP Series DC-DC Converter
Rev. 07-2007
General Specifications
Output short circuit protection Temperature rise at full load Cooling Operating temperature range Storage temperature range Soldering temperature Storage humidity range Case material MTBF Weight Continuous 15C typ., 35C max. Free air convection -40C to +85C -50C to +125C 300C (1.5mm from case for 10sec.) <95% Plastic (UL94-V0) >1,000,000 hrs. 6g
Isolation Specifications
Item Isolation Voltage Isolation Resistance Isolation Capacitance Test Conditions Flash tested for 1 min. Test at 500 Vdc Input/Output Min. 1500 1000 Typ. Max. Units Vdc M PF
80
Typical Characteristics
Ic
Vc
R
R Vc/Ic- 0.1 5
3 2 Lin 8 6
Ic:mA!( 5mA Typ) R: k
Vi n
+ Vo
Cin Cs
Cout 1 7
GND
0V
Outline Dimensions & Recommended Layout Pattern
0.50 [0.020]
12.00 [0.472]
1
2
3
5
6
7
8
date
4.00 [0.157] 0.50 [0.020]
5.08 2.10 [0.083] [0.200]
2.54 [0.100]
P in
1
2
3
5
6
7
8
Fun citon GN D V in C trl NC +Vo 0V CS
Note: Tolerances: (pin: 0.1(0.004); others: 0.25(0.01))
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
9.50 [0.374]
Bottom View
0.30 [0.012] 2.90 [0.114]
3/3
VWRBS3-SIP Series DC-DC Converter
Rev. 07-2007
Application Notes:
- All of the VWRBS3-SIP Series have been tested according to the following recommended testing circuit before leaving the factory. This series should be tested under load(Figure 1). If you want to further decrease the input/output ripple, you can increase capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high(Table 2).
- Input current Nominal input voltage range. The input current of the power supply must be sufficient to the startup current (Ip) of the DC/DC module (Figure 2)
CS Capacitor T able (Table 1)
Vout CS 5V 9V 12V 15V 24V 47uF-100uF 10uF-47uF
External Cap acitor T able (Table 2)
Vout 5 9 12 15 Cout (Max) 1000uF 680uF 470uF 330uF
- Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded. No parallel connection or plug and play.
Figure 1
Temperature Derating Graph
Operating Temp.( C )
- NC Terminals Unless otherwise specified, NC terminals of all series are used for converter's interior circuit connection, and are not allowed connection of any external circuit.; - CTRL Terminal When open or high impedance, the converter will work well; When this pin is `high'; the converter will shutdown; It should be noted that the input current should remain between 5-10mA,exceeding the maximum 20mA will cause permanent damage to the converter.
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258


▲Up To Search▲   

 
Price & Availability of VWRBS3-D12-S12-SIP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X